Biometric System Laboratory Biometric Test Center Pattern Recognition and Image Processing Laboratory Biometrics Research Lab - ATVS
FVC2006 is partially supported by BioSecure
Algorithm P024 on database DB2_A

EER
EER*
FMR100
FMR1000
ZeroFMR
ZeroFNMR
0.474%
0.474%
0.368%
0.682%
100.000%
33.731%

REJENROLL
REJNGRA
REJNIRA
0.00% (F:0 T:0 M:0 m:0 C:0)
0.00% (E:0 F:0 T:0 M:0 m:0 C:0)
0.00% (E:0 F:0 T:0 M:0 m:0 C:0)

AVG Enroll Time
AVG Match Time
AVG Match Time (G)
AVG Match Time (I)
0.214 sec
0.146 sec
0.076 sec
0.212 sec

AVG Model size
MAX Model size
MAX Enroll Memory
MAX Match Memory
2420 Bytes
3547 Bytes
3060 KBytes
3836 KBytes


Score distributions

FMR(t) and FNMR(t)

ROC curve






© 2006 Biometric System Laboratory - University of Bologna For information or suggestions: fvc2006@csr.unibo.it