Biometric System Laboratory Biometric Test Center Pattern Recognition and Image Processing Laboratory Biometrics Research Lab - ATVS
FVC2006 is partially supported by BioSecure
Algorithm P153 on database DB3_A

EER
EER*
FMR100
FMR1000
ZeroFMR
ZeroFNMR
7.491%
7.238%
10.974%
15.011%
25.000%
100.000%

REJENROLL
REJNGRA
REJNIRA
0.00% (F:0 T:0 M:0 m:0 C:0)
0.32% (E:0 F:0 T:30 M:0 m:0 C:0)
0.98% (E:0 F:0 T:95 M:0 m:0 C:0)

AVG Enroll Time
AVG Match Time
AVG Match Time (G)
AVG Match Time (I)
0.057 sec
0.082 sec
0.084 sec
0.081 sec

AVG Model size
MAX Model size
MAX Enroll Memory
MAX Match Memory
347 Bytes
740 Bytes
3824 KBytes
3840 KBytes


Score distributions

FMR(t) and FNMR(t)

ROC curve






© 2006 Biometric System Laboratory - University of Bologna For information or suggestions: fvc2006@csr.unibo.it